WHAT IS J1939 Gateway™ PLUS?
J1939 Gateway™ PLUS for a J1939 Data Logger and CAN bus Data Logger
Pre-configured and simple to modify product that converts any standard or proprietary PGN into about 80 protocols over four usable ports. Features include real-time data logging, Mail Server, Sync Server, Time Manager, and Virtual HMI Web Server
The J1939 Gateway™ PLUS is a “Plug & Play” data concentrator, protocol converter, J1939 data logger and CAN bus data logger. It can be pre-configured for your application so that all you have to do is install the unit and begin communication. If customization is needed in the field, you can use our free MonicoView II™ software to change port settings, adjust mapping, add field devices, and incorporate other protocols.
The J1939 Gateway PLUS™ has the same powerful features found in the J1939 Gateway™ with the addition of several key upgrades. With this version, you can take advantage of upgraded features such as remote monitoring via the Virtual HMI Web Server, SMTP and SMS mail servers, real-time data logging, ftp server to retrieve data log files, and a sync server to automatically sync log files with an IP connected computer.

Beyond a J1939 Data Logger and Remote CAN Protocol Converter
There is no better product than the J1939 Gateway PLUS™ for communicating over SAE J1939 and CANbus. Monico’s engineers and technical support specialists have spent extensive time working with customers in need of a remote CAN protocol converter, SAE J1939 communication, a J1939 data logger or can bus data logger, overall engine or genset monitoring and help integrating equipment into an overall monitoring system. We have worked in every industrial market and have a wide range of experience, so we are able to adapt our product to your specific needs.
The knowledge and expertise of the Monico staff, along with our top-notch post purchase support, is what makes our product stand out. The efforts we make to assure that our J1939 Gateway™ line of products will work for your application is what makes our products continually succeed in the marketplace. Our knowledge and hands-on experience with SAE J1939, CAN bus, industrial communications and the engine or generator brand you have on site will assure that this product works for you.
Benefits & Features
- Pre-configured solution that provides basic HMI screens over the internet
- C-UL approved for Class I Div II groups A-D locations
- SMTP Server and SMS Server for email notification of alarms and shutdowns
- Up to 2GB Compact Flash card that will store up to 200 days work of data
- Sync Server to copy data log files with an external server located on the network
- FTP Server to upload data log files from any location on the network
- Time Manager to automatically sync the real-time clock to a server or external source
- Full diagnostic and fault code support with text descriptions
- LED indication lights for communication and power confirmation
More information on the J1939 Gateway PLUS Features:
- Real-Time Data Logging: Multiple data logs can be implemented with varying timing formats and file structures. Up to a 2 GB Compact Flash memory card can be inserted which is capable of logging approximately 80 parameters every three seconds for 200 days. The logs are stored as raw and as CSV files which will import directly into Excel.
- SMTP and SMS Servers: The email servers allow the ability to trigger traditional email messages and text messages upon configurable circumstances.
- Sync Server: This server is programmable to push the log files to a server located on the same network.
- FTP Server: This server allows a user to transfer the log files automatically from a remote network.
- OPC Capability: This feature allows a common server to poll data from multiple protocols under one system in combination with OPC WORX Server Software.
- Time Manager: The Time Manager syncs the on-board real-time clock with a server standard or an internet standard clock. This is particularly useful when data logging
- Virtual HMI Web Server: The built-in web server allows remote monitoring and control of an engine from a remote location using only Internet Explorer. Security features are built-in to prevent unauthorized access. Standard Web Server screens are supplied or custom HTML web pages may be created.
Download Datasheet →

Future-proof your monitoring system
Looking for the Next Generation of Industrial Monitoring?
Monico’s mCore® SDR is the powerful evolution of our trusted gateway technology — combining protocol conversion, edge processing, and remote connectivity in one intelligent device. With onboard analytics, flexible I/O, and seamless integration to the cloud or MonicoLive™, mCore® SDR gives you more visibility, control, and scalability than ever before.

How to Choose The Right Gateway
Monico Gateway Product Comparison – Gateways vs. mCore® SDR
Feature / Use Case | ![]() CDL Gateway™ | ![]() CPC Gateway™ | ![]() J1939 Gateway™ | ![]() EMCP 3 & 4 Gateway™ | ![]() mCore® SDR |
---|---|---|---|---|---|
Primary Use | Monitoring Caterpillar® engines/gensets via CDL | Multi-device protocol conversion for varied industrial systems | Monitoring J1939 CAN-based engines and mobile equipment | Caterpillar® EMCP 3 & EMCP 4 controller data acquisition | Edge data acquisition, protocol conversion, analytics, and remote connectivity |
Supported Protocols | CDL (Cat Data Link) + selected outputs | 100+ protocols (Modbus, Siemens, BACnet, DeviceNet, etc.) | J1939 + supported outputs | Proprietary EMCP 3.x and EMCP 4.x protocols + Modbus, Ethernet/IP, etc. | 100+ protocols (Modbus, Ethernet/IP, MQTT, OPC UA, BACnet, etc.) |
Automatic Equipment Detection | ✔ Yes | ✔ Yes | ✔ Yes | ✔ Yes | ✔ Yes |
Edge Processing / Local Analytics | ❌ No | ❌ No | ❌ No | ❌ No | ✔ Yes – built-in logic engine, thresholding, event handling |
Cloud Connectivity | ❌ Requires integration | ❌ Requires integration | ❌ Requires integration | ❌ Requires integration | ✔ Yes – native support for MonicoLive™, MQTT, Azure, etc. |
Pre-configured Parameters | 400+ CDL registers | 400+ across multiple protocols | 100+ J1939 parameters | Pre-mapped EMCP 3 & 4 data points | ✔ Preloaded templates + customizable mapping |
Real-Time Data Polling Speed | 20–60 parameters/sec | 20–60 parameters/sec | ~20 parameters/sec | Moderate polling speed depending on controller model | ✔ High-speed, multi-threaded polling |
Custom Logic & Alerting | ❌ No | ❌ No | ❌ No | ❌ No | ✔ Yes – programmable alerts, conditions, and data-driven actions |
USB Interface for Diagnostics | ✔ Yes | ✔ Yes | ✔ Yes | ✔ Yes | ✔ Yes |
Built-in I/O Capability | Optional modules | Optional modules | Optional modules | Limited or none | ✔ Native I/O: analog, digital, RTD, thermocouple, relay options |
Ideal Equipment Type | CAT® engines, gensets (EMCP, 3400, 3500, etc.) | Engines, PLCs, drives, sensors in multi-vendor environments | Mobile equipment with J1939 CAN protocol | CAT® gensets using EMCP 3.x and EMCP 4.x control panels | Any industrial asset requiring smart monitoring, data forwarding, and edge intelligence |
Simultaneous Protocol Support | 1 input + configurable output | Up to 9 protocols simultaneously | 1 input + configurable output | 1 or 2 protocols | ✔ Multi-protocol support, field + cloud |
Installation Time | Minutes (plug-and-play) | Fast setup, custom config available | Quick install | Pre-configured, but may require protocol setup | ✔ Easy setup with intuitive tools + remote provisioning |
Target User | CAT® engine operators | Integrators managing mixed-protocol environments | Fleet owners using J1939 equipment | Operators of CAT® gensets using EMCP controllers | OEMs, industrial operators, and anyone modernizing with edge-to-cloud monitoring |
Hazardous Location Approval | ✔ Class I, Div II Groups A-D | ✔ Class I, Div II Groups A-D | ✔ Class I, Div II Groups A-D | ✔ Class I, Div II (where applicable) | ✔ Available in hazardous-location rated configurations |
Why Monico
Key advantages that set us apart

Your Data is Yours
Your data is securely collected and stored, always remaining under your control, so you can make informed decisions without concerns about data accessibility or third-party restrictions. We’re here to empower you with the insights you need, not limit how you use your data.

Preconfigured, No Coding Required
Our solutions come preconfigured and ready to deploy without the need for complex coding or development. This plug-and-play approach gets you up and running faster, no coding or data analysis required.

Modern Intuitive Platform
Our platform is designed with you in mind, combining modern functionality with an intuitive interface that simplifies data monitoring and visualization. With Monico, you’ll experience an easy-to-navigate system that makes it simple to access, interpret, and act on your data.

OEM-Agnostic, Multi-Protocol Support
Our gateways are preconfigured for your specific equipment and work seamlessly with most major industrial OEMs. With broad protocol support, they easily integrate into mixed fleets—no custom coding or complex setup required.

EASY AS 1,2,3
The Shortest Path to Real-Time
Actionable Intelligence™
1
Schedule a Demo
We’ll walk you through the process and share examples grounded in real data. No big sales pitch. We’ll discuss the problems you’re trying to solve, identify your needs and address your questions about ROI, security, the implementation process, and more.
2
Let Us Configure Your Solution
We won’t just sell you a gateway and wish you luck. Our powerful solutions are simplified for each customer by being pre-configured, down to the serial number of each asset. You’ll easily access data and gain insights from day one, without struggling with siloed data or differing protocols.
3
Count On Us for Support
Our job isn’t done until implementation is successful and you’re getting data exactly the way you want it, where you want it. We’ll provide installation, training and support. In addition, our online resource library is available 24/7.
FAQs
Frequently Asked Questions
What does the J1939 Gateway™ do?
The J1939 Gateway™ is a pre-configured device that reads SAE J1939 data over a CAN bus network and translates it into one of 80+ industrial protocols. It’s designed to make it easy to integrate J1939 engine data into SCADA, PLC, or remote monitoring systems.
What types of equipment use J1939?
J1939 is commonly used in mobile and industrial diesel engines — including equipment from Cummins, John Deere, Perkins, Deutz, Detroit Diesel, and others. It’s also the standard protocol for non-Caterpillar® gensets and many off-highway or transport assets.
How is Monico’s J1939 Gateway™ different from others on the market?
Unlike most converters, the J1939 Gateway™ balances pre-configured simplicity with deep protocol flexibility. It supports both standard and proprietary PGNs and translates them into major protocols like Modbus, BACnet, SNMP, and Allen Bradley — with minimal setup required.
Can I convert proprietary PGNs, or just standard ones?
Yes, you can do both. The Gateway supports conversion of any standard or proprietary PGN, allowing it to work with custom engine implementations or manufacturer-specific extensions.
What data can I monitor using this gateway?
You can access key engine parameters such as RPM, coolant temp, fuel rate, engine hours, fault codes, and more — depending on what your engine supports over J1939. The Gateway includes hundreds of pre-mapped registers out of the box.
How many communication protocols are supported?
Over 80 output protocols are supported, including industry standards like Modbus RTU/TCP, BACnet/IP, Ethernet/IP, Allen Bradley (SLC and ControlLogix), GE Fanuc, Siemens, and SNMP. The Gateway can communicate on up to four ports simultaneously (serial and Ethernet).
Is it compatible with Caterpillar® engines?
Yes — specifically EMCP 3 and 4 series gensets, which use J1939 instead of Cat Data Link (CDL). For other CAT equipment using CDL, Monico’s CDL Gateway™ would be the better fit.
Is the Gateway easy to install and configure?
Yes. The J1939 Gateway™ is C-UL listed for Class I, Div II Groups A-D, meaning it’s safe for use in hazardous or industrial areas like oil & gas or marine applications.
Can I add more than engine data to my system?
Yes. Optional I/O modules allow you to integrate additional signals like fuel level, bearing temperature, analog inputs, and digital controls — giving you a more complete monitoring system around the engine.
How fast does the Gateway collect data?
It polls data at speeds of 20–60 parameters per second, depending on network traffic and engine configuration — enabling real-time visibility into engine performance.