Skip to main content

J1939 Gateway PLUS

Home > Monitoring > Legacy Gateways > J1939 Gateway PLUS

WHAT IS J1939 Gateway™ PLUS?

J1939 Gateway™ PLUS for a J1939 Data Logger and CAN bus Data Logger

Pre-configured and simple to modify product that converts any standard or proprietary PGN into about 80 protocols over four usable ports. Features include real-time data logging, Mail Server, Sync Server, Time Manager, and Virtual HMI Web Server

The J1939 Gateway™ PLUS is a “Plug & Play” data concentrator, protocol converter, J1939 data logger and CAN bus data logger. It can be pre-configured for your application so that all you have to do is install the unit and begin communication. If customization is needed in the field, you can use our free MonicoView II™ software to change port settings, adjust mapping, add field devices, and incorporate other protocols.

The J1939 Gateway PLUS™ has the same powerful features found in the J1939 Gateway™ with the addition of several key upgrades. With this version, you can take advantage of upgraded features such as remote monitoring via the Virtual HMI Web Server, SMTP and SMS mail servers, real-time data logging, ftp server to retrieve data log files, and a sync server to automatically sync log files with an IP connected computer.

Beyond a J1939 Data Logger and Remote CAN Protocol Converter

There is no better product than the J1939 Gateway PLUS™ for communicating over SAE J1939 and CANbus. Monico’s engineers and technical support specialists have spent extensive time working with customers in need of a remote CAN protocol converter, SAE J1939 communication, a J1939 data logger or can bus data logger, overall engine or genset monitoring and help integrating equipment into an overall monitoring system. We have worked in every industrial market and have a wide range of experience, so we are able to adapt our product to your specific needs.

The knowledge and expertise of the Monico staff, along with our top-notch post purchase support, is what makes our product stand out. The efforts we make to assure that our J1939 Gateway™ line of products will work for your application is what makes our products continually succeed in the marketplace. Our knowledge and hands-on experience with SAE J1939, CAN bus, industrial communications and the engine or generator brand you have on site will assure that this product works for you.

Benefits & Features

  • Pre-configured solution that provides basic HMI screens over the internet
  • C-UL approved for Class I Div II groups A-D locations
  • SMTP Server and SMS Server for email notification of alarms and shutdowns
  • Up to 2GB Compact Flash card that will store up to 200 days work of data
  • Sync Server to copy data log files with an external server located on the network
  • FTP Server to upload data log files from any location on the network
  • Time Manager to automatically sync the real-time clock to a server or external source
  • Full diagnostic and fault code support with text descriptions
  • LED indication lights for communication and power confirmation

More information on the J1939 Gateway PLUS Features:

  • Real-Time Data Logging: Multiple data logs can be implemented with varying timing formats and file structures. Up to a 2 GB Compact Flash memory card can be inserted which is capable of logging approximately 80 parameters every three seconds for 200 days. The logs are stored as raw and as CSV files which will import directly into Excel.
  • SMTP and SMS Servers: The email servers allow the ability to trigger traditional email messages and text messages upon configurable circumstances.
  • Sync Server: This server is programmable to push the log files to a server located on the same network.
  • FTP Server: This server allows a user to transfer the log files automatically from a remote network.
  • OPC Capability: This feature allows a common server to poll data from multiple protocols under one system in combination with OPC WORX Server Software.
  • Time Manager: The Time Manager syncs the on-board real-time clock with a server standard or an internet standard clock. This is particularly useful when data logging
  • Virtual HMI Web Server: The built-in web server allows remote monitoring and control of an engine from a remote location using only Internet Explorer. Security features are built-in to prevent unauthorized access. Standard Web Server screens are supplied or custom HTML web pages may be created.

Download Datasheet →

Looking for the Next Generation of Industrial Monitoring?

Monico’s mCore® SDR is the powerful evolution of our trusted gateway technology — combining protocol conversion, edge processing, and remote connectivity in one intelligent device. With onboard analytics, flexible I/O, and seamless integration to the cloud or MonicoLive™, mCore® SDR gives you more visibility, control, and scalability than ever before.

How to Choose The Right Gateway

Monico Gateway Product Comparison – Gateways vs. mCore® SDR

Feature / Use Case
CDL Gateway™

CPC Gateway™

J1939 Gateway™

EMCP 3 & 4 Gateway™

mCore® SDR
Primary UseMonitoring Caterpillar® engines/gensets via CDLMulti-device protocol conversion for varied industrial systemsMonitoring J1939 CAN-based engines and mobile equipmentCaterpillar® EMCP 3 & EMCP 4 controller data acquisitionEdge data acquisition, protocol conversion, analytics, and remote connectivity
Supported ProtocolsCDL (Cat Data Link) + selected outputs100+ protocols (Modbus, Siemens, BACnet, DeviceNet, etc.)J1939 + supported outputsProprietary EMCP 3.x and EMCP 4.x protocols + Modbus, Ethernet/IP, etc.100+ protocols (Modbus, Ethernet/IP, MQTT, OPC UA, BACnet, etc.)
Automatic Equipment Detection✔ Yes✔ Yes✔ Yes✔ Yes✔ Yes
Edge Processing / Local Analytics❌ No❌ No❌ No❌ No✔ Yes – built-in logic engine, thresholding, event handling
Cloud Connectivity❌ Requires integration❌ Requires integration❌ Requires integration❌ Requires integration✔ Yes – native support for MonicoLive™, MQTT, Azure, etc.
Pre-configured Parameters400+ CDL registers400+ across multiple protocols100+ J1939 parametersPre-mapped EMCP 3 & 4 data points✔ Preloaded templates + customizable mapping
Real-Time Data Polling Speed20–60 parameters/sec20–60 parameters/sec~20 parameters/secModerate polling speed depending on controller model✔ High-speed, multi-threaded polling
Custom Logic & Alerting❌ No❌ No❌ No❌ No✔ Yes – programmable alerts, conditions, and data-driven actions
USB Interface for Diagnostics✔ Yes✔ Yes✔ Yes✔ Yes✔ Yes
Built-in I/O CapabilityOptional modulesOptional modulesOptional modulesLimited or none✔ Native I/O: analog, digital, RTD, thermocouple, relay options
Ideal Equipment TypeCAT® engines, gensets (EMCP, 3400, 3500, etc.)Engines, PLCs, drives, sensors in multi-vendor environmentsMobile equipment with J1939 CAN protocolCAT® gensets using EMCP 3.x and EMCP 4.x control panelsAny industrial asset requiring smart monitoring, data forwarding, and edge intelligence
Simultaneous Protocol Support1 input + configurable outputUp to 9 protocols simultaneously1 input + configurable output1 or 2 protocols✔ Multi-protocol support, field + cloud
Installation TimeMinutes (plug-and-play)Fast setup, custom config availableQuick installPre-configured, but may require protocol setup✔ Easy setup with intuitive tools + remote provisioning
Target UserCAT® engine operatorsIntegrators managing mixed-protocol environmentsFleet owners using J1939 equipmentOperators of CAT® gensets using EMCP controllersOEMs, industrial operators, and anyone modernizing with edge-to-cloud monitoring
Hazardous Location Approval✔ Class I, Div II Groups A-D✔ Class I, Div II Groups A-D✔ Class I, Div II Groups A-D✔ Class I, Div II (where applicable)✔ Available in hazardous-location rated configurations

Applications

Why Monico

Key advantages that set us apart

Your Data is Yours

Preconfigured, No Coding Required

Modern Intuitive Platform

OEM-Agnostic, Multi-Protocol Support

The Shortest Path to Real-Time
Actionable Intelligence™

1

Schedule a Demo

We’ll walk you through the process and share examples grounded in real data. No big sales pitch. We’ll discuss the problems you’re trying to solve, identify your needs and address your questions about ROI, security, the implementation process, and more.

2

Let Us Configure Your Solution

We won’t just sell you a gateway and wish you luck. Our powerful solutions are simplified for each customer by being pre-configured, down to the serial number of each asset. You’ll easily access data and gain insights from day one, without struggling with siloed data or differing protocols.

3

Count On Us for Support

Our job isn’t done until implementation is successful and you’re getting data exactly the way you want it, where you want it. We’ll provide installation, training and support. In addition, our online resource library is available 24/7.

FAQs

Frequently Asked Questions

What does the J1939 Gateway™ do?

The J1939 Gateway™ is a pre-configured device that reads SAE J1939 data over a CAN bus network and translates it into one of 80+ industrial protocols. It’s designed to make it easy to integrate J1939 engine data into SCADA, PLC, or remote monitoring systems.

What types of equipment use J1939?

J1939 is commonly used in mobile and industrial diesel engines — including equipment from Cummins, John Deere, Perkins, Deutz, Detroit Diesel, and others. It’s also the standard protocol for non-Caterpillar® gensets and many off-highway or transport assets.

How is Monico’s J1939 Gateway™ different from others on the market?

Unlike most converters, the J1939 Gateway™ balances pre-configured simplicity with deep protocol flexibility. It supports both standard and proprietary PGNs and translates them into major protocols like Modbus, BACnet, SNMP, and Allen Bradley — with minimal setup required.

Can I convert proprietary PGNs, or just standard ones?

Yes, you can do both. The Gateway supports conversion of any standard or proprietary PGN, allowing it to work with custom engine implementations or manufacturer-specific extensions.

What data can I monitor using this gateway?

You can access key engine parameters such as RPM, coolant temp, fuel rate, engine hours, fault codes, and more — depending on what your engine supports over J1939. The Gateway includes hundreds of pre-mapped registers out of the box.

How many communication protocols are supported?

Over 80 output protocols are supported, including industry standards like Modbus RTU/TCP, BACnet/IP, Ethernet/IP, Allen Bradley (SLC and ControlLogix), GE Fanuc, Siemens, and SNMP. The Gateway can communicate on up to four ports simultaneously (serial and Ethernet).

Is it compatible with Caterpillar® engines?

Yes — specifically EMCP 3 and 4 series gensets, which use J1939 instead of Cat Data Link (CDL). For other CAT equipment using CDL, Monico’s CDL Gateway™ would be the better fit.

Is the Gateway easy to install and configure?

Yes. The J1939 Gateway™ is C-UL listed for Class I, Div II Groups A-D, meaning it’s safe for use in hazardous or industrial areas like oil & gas or marine applications.

Can I add more than engine data to my system?

Yes. Optional I/O modules allow you to integrate additional signals like fuel level, bearing temperature, analog inputs, and digital controls — giving you a more complete monitoring system around the engine.

How fast does the Gateway collect data?

It polls data at speeds of 20–60 parameters per second, depending on network traffic and engine configuration — enabling real-time visibility into engine performance.