Skip to main content

CPC Gateway

Home > Monitoring > Legacy Gateways > CPC Gateway

WHAT IS CPC Gateway?

More Than Just a Custom Protocol Converter

A flexible device supporting about 100 protocols used to collect information from a myriad of devices that use multiple protocols over multiple ports and put all the information in a common format.

Our CPC Gateway™ is a custom protocol converter that works with a long list of protocols and devices to take any standard or proprietary protocol used in industrial communications and translate the data collected into a usable format for communication to maintenance or technical staff or for integration into an overall monitoring system. This genset and engine monitoring gateway can convert data messages, events and commands into the format that fits your needs.

CPC Gateway – Your Engine Monitoring Gateway

With a list of features that includes user configurable port settings and addresses, modular jacks to prevent wiring errors, and the ability to support over 100 protocols, including well known names such as Allen Bradley, GE Fanuc, Siemens, Modbus, BACnet, CANopen, Schneider, Ethernet IP and Honeywell, our custom protocol converter really does much more. It allows for a set-up that is simple and quick for any qualified technician with basic computer skills, and makes our engine monitoring Gateway stand out from its competitors through its flexibility, ease of use and capabilities.

Monico’s Custom Protocol Gateway is an extremely flexible device with four to six physical ports which can communicate in up to nine protocols simultaneously. It supports an average of 100 protocols, with more being added on a regular basis, and can be used to collect information from a myriad of devices which use multiple protocols over multiple ports and then put all the information in a common, pre-configured data map. It can be used to connect Allen Bradley, GE Fanuc, Siemens, and Schnieder PLC’s into one functional network as well as many other devices.

Benefits & Features

  • Over 400 pre-configured solutions
  • C-IL approved for Class I Div II groups A-D locations
  • 0-15 times faster than other customer communications products
  • Automatic engine detection and configuration
  • Built-in USB interface shows all available parameters on a specific installation
  • Gather data from other assets through available ports
  • LED indication lights for communication and power confirmation
  • Full diagnostic and fault code support with text descriptions
  • Pulls parameters at a rate of approximately 20-60 parameters per second

Available Ports:

  • RS-232 port via RJ-11 Jack
  • RS-485 via RJ-45 Jack (2-wire or 4-wire) 
  • Ethernet via RJ-45 Jack 
  • Serial Expansion Card with an additional RS-232 and RS-485 port 
  • Additional Ports via expansion cards such as a Caterpillar® Data Link, CANbus, ProfiBus, and DeviceNet 

Custom Protocol Converter

We named this product CPC, or Custom Protocol Converter, because of our ability to custom configure it to pull the protocol your equipment uses and convert the pulled data into the protocol you want outputted to your specific monitoring system. Whereas the CDL Gateway and J1939 Gateway communicate through the primary output of CDL or J1939, this Gateway can collect information from an input other than CDL or CAN bus.

Available Protocols & Compatible Devices:

AC Tech | Adam | Allen Bradley | Alstom | Automated Direct | BACnet | Banner Beckhoff ADS | CAN J1939 & CANOpen | Caterpillar® Data Link | Control Techniques | Cruisair | CTC | Delta Computer | Devicenet | Dupline | Ethernet IP | EZ Automation | Festco | FloCom | Garmin NMEA 0183 | GE | Giddings 7 Lewis | HBM | Honeywell | IDEC | IFM | IMO | Indramat | Intelligent Actuator | Ircon | KEB | Keyence | King | Klockner Moeller | KollMorgan 400/600 | Koyo | Krohne | Lenze | Matsushita | Profibus | Quicksilver | Red Lion Controls | Rexroth | Schneider | SEW | Siemens | SSD Drives/Eurotherm | Telemechanique | Toshiba | Unitronics | Yaskawa | Yokogawa

Download Datasheet →

Looking for the Next Generation of Industrial Monitoring?

Monico’s mCore® SDR is the powerful evolution of our trusted gateway technology — combining protocol conversion, edge processing, and remote connectivity in one intelligent device. With onboard analytics, flexible I/O, and seamless integration to the cloud or MonicoLive™, mCore® SDR gives you more visibility, control, and scalability than ever before.

How to Choose The Right Gateway

Monico Gateway Product Comparison – Gateways vs. mCore® SDR

Feature / Use Case
CDL Gateway™

CPC Gateway™

J1939 Gateway™

EMCP 3 & 4 Gateway™

mCore® SDR
Primary UseMonitoring Caterpillar® engines/gensets via CDLMulti-device protocol conversion for varied industrial systemsMonitoring J1939 CAN-based engines and mobile equipmentCaterpillar® EMCP 3 & EMCP 4 controller data acquisitionEdge data acquisition, protocol conversion, analytics, and remote connectivity
Supported ProtocolsCDL (Cat Data Link) + selected outputs100+ protocols (Modbus, Siemens, BACnet, DeviceNet, etc.)J1939 + supported outputsProprietary EMCP 3.x and EMCP 4.x protocols + Modbus, Ethernet/IP, etc.100+ protocols (Modbus, Ethernet/IP, MQTT, OPC UA, BACnet, etc.)
Automatic Equipment Detection✔ Yes✔ Yes✔ Yes✔ Yes✔ Yes
Edge Processing / Local Analytics❌ No❌ No❌ No❌ No✔ Yes – built-in logic engine, thresholding, event handling
Cloud Connectivity❌ Requires integration❌ Requires integration❌ Requires integration❌ Requires integration✔ Yes – native support for MonicoLive™, MQTT, Azure, etc.
Pre-configured Parameters400+ CDL registers400+ across multiple protocols100+ J1939 parametersPre-mapped EMCP 3 & 4 data points✔ Preloaded templates + customizable mapping
Real-Time Data Polling Speed20–60 parameters/sec20–60 parameters/sec~20 parameters/secModerate polling speed depending on controller model✔ High-speed, multi-threaded polling
Custom Logic & Alerting❌ No❌ No❌ No❌ No✔ Yes – programmable alerts, conditions, and data-driven actions
USB Interface for Diagnostics✔ Yes✔ Yes✔ Yes✔ Yes✔ Yes
Built-in I/O CapabilityOptional modulesOptional modulesOptional modulesLimited or none✔ Native I/O: analog, digital, RTD, thermocouple, relay options
Ideal Equipment TypeCAT® engines, gensets (EMCP, 3400, 3500, etc.)Engines, PLCs, drives, sensors in multi-vendor environmentsMobile equipment with J1939 CAN protocolCAT® gensets using EMCP 3.x and EMCP 4.x control panelsAny industrial asset requiring smart monitoring, data forwarding, and edge intelligence
Simultaneous Protocol Support1 input + configurable outputUp to 9 protocols simultaneously1 input + configurable output1 or 2 protocols✔ Multi-protocol support, field + cloud
Installation TimeMinutes (plug-and-play)Fast setup, custom config availableQuick installPre-configured, but may require protocol setup✔ Easy setup with intuitive tools + remote provisioning
Target UserCAT® engine operatorsIntegrators managing mixed-protocol environmentsFleet owners using J1939 equipmentOperators of CAT® gensets using EMCP controllersOEMs, industrial operators, and anyone modernizing with edge-to-cloud monitoring
Hazardous Location Approval✔ Class I, Div II Groups A-D✔ Class I, Div II Groups A-D✔ Class I, Div II Groups A-D✔ Class I, Div II (where applicable)✔ Available in hazardous-location rated configurations

Applications

Why Monico

Key advantages that set us apart

Your Data is Yours

Preconfigured, No Coding Required

Modern Intuitive Platform

OEM-Agnostic, Multi-Protocol Support

The Shortest Path to Real-Time
Actionable Intelligence™

1

Schedule a Demo

We’ll walk you through the process and share examples grounded in real data. No big sales pitch. We’ll discuss the problems you’re trying to solve, identify your needs and address your questions about ROI, security, the implementation process, and more.

2

Let Us Configure Your Solution

We won’t just sell you a gateway and wish you luck. Our powerful solutions are simplified for each customer by being pre-configured, down to the serial number of each asset. You’ll easily access data and gain insights from day one, without struggling with siloed data or differing protocols.

3

Count On Us for Support

Our job isn’t done until implementation is successful and you’re getting data exactly the way you want it, where you want it. We’ll provide installation, training and support. In addition, our online resource library is available 24/7.

FAQs

Frequently Asked Questions

What is the CPC Gateway™ used for?

The CPC Gateway™ (Custom Protocol Converter) is a powerful, multi-protocol device that collects data from a wide variety of industrial equipment using different communication standards and unifies that data into a single, consistent format — ideal for engine and genset monitoring, as well as broader plant-wide integration.

What types of protocols and devices are supported?

The CPC Gateway™ supports a vast list of both standard and proprietary protocols. It can connect to PLCs, drives, sensors, and other industrial devices from manufacturers like GE Fanuc, Schneider, Siemens, Yaskawa, and many more. Protocols include CANopen, Ethernet IP, DeviceNet, ProfiBus, and Caterpillar® Data Link, among others.

Can I monitor engines and generator sets with this device?

Yes. While it’s broader than a single-brand solution like the CDL Gateway™, the CPC Gateway™ excels in multi-equipment environments where engines, gensets, and auxiliary systems must be monitored together using different protocols.

What’s the typical data polling speed?

The device pulls data at a rate of roughly 20–60 parameters per second, depending on the protocol and setup. This high throughput supports real-time monitoring of complex systems.

Can this gateway be used in multi-vendor environments?

Absolutely. It’s ideal for complex environments where different OEM devices need to be brought into a single monitoring or control system. Whether you’re bridging legacy equipment with modern SCADA or unifying data from multiple vendor PLCs, the CPC Gateway™ provides the necessary flexibility.

How is the CPC Gateway™ different from other protocol converters?

Most converters support only a handful of protocols and one-to-one communication. The CPC Gateway™ supports up to nine protocols simultaneously, across four to six physical ports, and works with over 100 industrial protocols — including Allen Bradley, Modbus, Siemens, BACnet, Honeywell, and more.

How does the CPC Gateway™ simplify integration?

By translating various inputs into a common, pre-configured data map, the CPC Gateway™ eliminates the complexity of mapping and formatting data manually. It enables seamless integration between disparate systems without custom coding or complicated middleware.

How customizable is the CPC Gateway™?

Extremely. Monico engineers can configure the Gateway to pull data from non-standard sources and output it in the exact protocol or data structure required by your control or monitoring system. This customization is what makes it a “custom” protocol converter.

Is this device safe for use in hazardous environments?

Yes. The CPC Gateway™ is C-IL approved for Class I, Div II Groups A-D hazardous locations, making it suitable for use in environments like oil and gas, marine, and heavy industrial settings.

How quickly can I get a CPC Gateway™ up and running?

Thanks to Monico’s pre-configured solutions and intuitive USB interface, installation is quick and setup can often be completed by any technician with basic computer skills. There’s no need to manually map registers — the data is already formatted for integration.